Freescale Kinetis K8x MCU family combines security features and performance and is so safe for IoT networking about of sale terminals.
The implementation of a secure embedded application has been made up to three ICs required, including the main processor, a coprocessor for cryptographic security functions and in some cases, an IC for a physical sabotage protection.
Kinetis K8x MCU family combines all these functions into a single MCU, thus saving costs, space and power. Kinetis K8x
By integrating powerful security functions in this MCU family for the broad market Freescale contributes to the safe networking of IoT applications (Internet of Things) as POS terminals, smart energy gateways, home automation and building management, portable medical and wearables.
Act "MCUs for the broad market as a catalyst for innovative final applications. For the further evolution of IoT such MCUs for new product developments to ensure maximum safety, "explains Steve Tateosian, for microcontroller platforms executive director in the Microcontroller Division of Freescale. "Freescale has been a leader in securing IoT end nodes. We are expanding our portfolio of security features for Kinetis based MCU products ever made, and we have our new K8x MCU family designed so that they can master even future security problems in IoT. "
First ARM Cortex-M MCU with hardware-based cryptography
Kinetis K8x is so Freescale, the first multi-application MCU family based on the ARM Cortex-M technology with hardware-based cryptography.
This should bring significant benefits for the cryptographic throughput with it. Authentication takes an order of magnitude faster than with pure software implementations, the program memory is relieved, the energy efficiency increases and the latest communication protocols are operated.
Kinetis K8x MCU family with patent-pending 'on-the-fly decryption' for external serial NOR flash supports a version of the encrypted external memory and provides in this way secure scalability.
Integrated sabotage prevention functions on the Kinetis K8x MCU family protect against both physical and passive attacks. In total, these advanced technologies ensure first-class security for a wide range of applications.
Monday, July 6, 2015
Friday, July 3, 2015
Samsung will continue to provide flash pass positive tests for iPhone 6s
It is reported that China Mobile, Samsung is in contact with Apple, provides NAND flash memory in talks for the upcoming release of iPhone 6s series. Informed sources also revealed that Samsung is the Xi'an facility to test its stability and reliability of flash memory chips.
Samsung did not give current iPhone 6 family provides flash memory chips, allegedly because the two companies do not agree on price. According to Credit Suisse (Credit Suisse) report shows that Toshiba provides iPhone 6 series 50% of flash memory chips, Hynix 30%, the remaining 20% of SanDisk (SanDisk) are also available.
Allegedly, Apple is planning to provide additional capacity of 64G iPhone models, because Chinese and European demand for this model great cooperation deal Samsung Apple iPhone 6s may be used for the flash memory chips. It is not clear Apple iPhone 6s series of products accounted for Samsung's memory chips have much.
It seems Samsung will play a very important role in the iPhone 6s series production, there are rumors that Apple is also enabled Samsung to help them do most of the production of iPhone 6s series A9 chips, although there are other reports that TSMC is the current iPhone 6 Series A8 The main supplier of the chip, the vendor will continue this year, Apple offers A9 chip.
Apple is expected to release in September this year, iPhone 6s and 6S Plus, but until the new listing, after the multiple capacity version comes out we can see the truth of the incident.
Wednesday, July 1, 2015
Apple announced HomeKit Siri instruction Smart Home Development Analysis
HomeKit system equipped with devices coming soon, Apple recently released a list of HomeKit Siri instructions, instructions contained adjust lighting, temperature control, coffee machine and printer mounted device open and close treatment, despite instructions not rich, but to meet the user daily home needs. HomeKit Apple introduced the first smart home platform, built-in features include door locks, lights, thermostat, network, HomeKit needed for the operation of third-party hardware products in collaboration with Siri is completed.
With Apple's smart home platform by developers to application stage, the smart home industry also will enter a substantial pace. Under the "Internet +" effect, intelligent appliances, connected to each other as a whole, all function controls integrated in a portable smart devices (such as smart phones, etc.), intelligent home life is becoming the mainstream of development. Foreign Apple, Google is constantly exerting force, the domestic market, millet, music, as, Haier, Midea, Wanda, and other businesses are actively force the smart home, smart home industry which led to the development of China.
At present, China potential smart home users have more than 100 million people, under the continuing impact of the Internet, the industry is expected in 2015 of smart home industry scale up to 124 billion yuan. 2013 of the smart appliance market size of over 100 billion yuan, is expected to market size in 2025 is expected to rise to 1 trillion yuan, intelligent hardware and software vendors will receive a major positive.
Apple announced HomeKit Siri instruction Smart Home Development Analysis
However, by the impact of the development time is not long, our smart home industry, there are technical standards are not uniform, inflated prices and product experience disadvantages such as poor. This requires hardware and software vendors to strengthen cooperation and expand the scope of cooperation in different fields, and promote the establishment of industry standards, improve concurrent power technology, improve product quality, to improve this situation. Apple released a smart home platform directive is the industry a good start, which will attract industry polymerized together in the development of the whole industry chain of intelligent, smart home industry will enter a rapid development stage.
Thursday, June 25, 2015
Just a drop of blood the new sensor can measure cancer and cholera
According to the latest issue of "Journal of the American Chemical Society," it reported that the International team includes Canadian researchers have developed a new, including graphene sensors. The biosensor to detect cholera toxin not only has a very high sensitivity, but also provide early diagnosis for cancer and other diseases. Surface plasmon resonance (SPR) sensor is a medical diagnosis of optical technology for high sensitivity and specificity. The researchers found that adding graphene may cause SPR sensor signal multiplied, so that a single molecule can anchor an ultrathin layer of a particular disease signal.
The sensor can detect within minutes of the cholera toxin, by contrast, the current detection techniques require hours or even days. The technology can also be extended to detect almost any including cancer disease markers.
The researchers said that in addition to faster and greatly improved due to the sensitivity of the sensor can be more easily detected small amounts of biological markers, in order to create conditions for the early diagnosis and prognosis of cancer and other diseases. This means that, just use a drop of blood sample from a patient acupuncture, can detect the biomarkers of disease.
SPR biosensor is significantly larger than the standard enzyme-linked immunosorbent assay (ELISA) has a higher sensitivity, laboratory-grown graphene proof than before the use of other forms of graphene is more suitable for the development of new sensors. Graphene is called chemical vapor deposition growth technique to create a large-area graphene nearly defect-free, uniform surface of the graphene helps amplifying the sensor signal.
Tuesday, June 23, 2015
Electromagnetic interference shielding data center cabling system
1, interfering with the data center cabling system
Cabling system consists of several subsystems, signal size of each subsystem used, frequency, etc. are not the same height, so there is interference, as well as the mutual interference between the various loads. To sum up, the integrated wiring system has the following sources of interference.
1.1 sources of interference from the data center within the building
(1) distribution network and the distribution box to generate high-frequency interference.
(2) high-power electric motor electric spark generated by harmonic interference.
(3) fluorescent lamps, electronic ballasts produce interference.
(4) High-frequency switching power supply interference.
(5) generated by the telephone ringing current interference.
(6) Information processing device generates periodic pulse interference.
If the cabling system can not keep a safe distance from these sources may be used to reduce or eliminate shielding system interference sources above the interference of cabling system.
1.2 the source of interference from outside the data center building
Sources of interference from outside the data center architecture are:
Radar, radio transmission equipment, mobile phone base stations, high-voltage wire, electrified railways, lightning strike zones in the interference signal environment and so on.
Obviously intelligent building external interference sources have a high electric field strength, when external cabling systems exist one or more sources of interference should be shielded system.
1.3 sources of interference from the surrounding environment cabling system
Cabling system noise level ambient interference signal field strength or integrated wiring system also should be shielded to protect the system exceeds the following requirements.
(1) computer local area network, if the frequency of the interference signal is introduced l0kHz ~ 600MHz, its field strength of 1V / m; frequency of 600MHz ~ 2.8GHz interference signal field strength of 5V / m.
(2) telecommunications terminal equipment, is introduced through the signal line and other DC or AC frequency of the interfering signal introduced into 15 ~ 80MHz, the field strength of 3V / m (amplitude modulation 80%, 1kHz).
Terminal Equipment (3) with analog / digital terminal interface to provide telephone service, the noise level exceeds 40dB total bandwidth should be less than 200MHz.
(4) The background noise level should be at least 12dB smaller than the reference.
2, comprehensive sets of wiring system anti-jamming measures
Electric field strength interference waves emitted cabling system exceeds a predetermined value, whether factors that need protective measures is more complex, which is the most harmful anti-electromagnetic interference and electromagnetic radiation. EMI issues related to the cabling system can work properly; electromagnetic radiation is related to the safety of cabling system under normal operating conditions information from being stolen by other persons, or causing electromagnetic pollution.
Conducting integrated wiring systems engineering design must be in accordance with the requirements of the construction unit, carry out a detailed arrangement and design, selecting appropriate protective measures.
2.1 shielding measures to reduce electromagnetic interference
Metal casing (1) Information systems, cable shield and metal trunking and other buildings in the introduction frame or equipotential bonding. Information system lightning protection zone in which the magnetic field strength attenuation should be calculated, to take appropriate measures to shield according to the results.
(2) The data center should not be located in high-rise buildings, should lower center of the building. Related equipment to try to stay away from the building facade. Take appropriate measures in accordance with the requirements of lightning protection zones shield and information equipment, electromagnetic field generated when the lightning to the inner decay.
(3) The information device is a non-metallic housing and the shield of the building did not meet the requirements, the importance of information equipment room or equipment based on the direct installation of metal screen or shielded room, shielded metal shielded rooms and other potential connection with phase.
Outdoor line of shielding measures 2.2
Outdoor wiring shield to note the following.
(1) the need to protect the local potential should use shielded cables and both ends of the shielding layer is peer connections, the shield after the junction of the lightning protection zones should also be equipotential connection.
(2) the use of the cable metal-containing components, shall at all into the household of the metal plugs, metal tidal layer and the metal strengthening the core metal member equipotential connection.
Room (3) Building interconnecting cables should be laid in a metal pipe, metal pipe ends to be connected to other potential electrical connections and connections to bring each building. Cable conduits must be equipotential connection. If between adjacent buildings have power and communication cables, the grounding device should be connected to each other.
2.3 Strengthening internal cabling system structure and materials of immunity
This is mainly possible electromagnetic interference requirements for products and equipment may be affected by electromagnetic interference raised. Specific requirements in the manufacturing process is tested to the appropriate standard.
Overall, computer equipment, communications equipment and electronic equipment and other products shape the structure should be made of a metal material box, box, cabinet or shelf, making it in the form of a Faraday cage, a ground terminal, and well grounded. This ability to somehow enhance immunity and radiation protection equipment.
For cable selection Cabling system must meet the system requirements, combined with the buildings surrounding electromagnetic environment into account, usually anti-jamming capability and transmission capacity is the major consideration, but also to consider the economic cost.
Select cables and cabling system connecting hardware, when determining whether a category that you want to ensure consistency. If you choose to shield the cables and connecting hardware must be shielded, and have a good grounding system. Link cabling system commonly used twisted pair, UTP has the ability to absorb and emit electromagnetic waves.
2.4 Note from the equipment and transmission lines between the different sources of interference
In addition to the use of shielded cabling system, well grounded in order to improve their own immunity, radiation protection, but also as far away from interference sources, in order to reduce its impact on the normal operation of the system, improve the reliability of systems and equipment to make Data center cabling system truly become a standard, standard cabling system.
Through a number of experiments shows that when the interference source distance transmission line at different distances, the distortion degree of the transmission signal is different. Therefore, in the construction and installation process should pay attention to the relationship between the wiring system and the distance from the source of disturbance, in strict accordance with standard design, construction, and make the appropriate testing to ensure normal and reliable cabling system.
Cabling system consists of several subsystems, signal size of each subsystem used, frequency, etc. are not the same height, so there is interference, as well as the mutual interference between the various loads. To sum up, the integrated wiring system has the following sources of interference.
1.1 sources of interference from the data center within the building
(1) distribution network and the distribution box to generate high-frequency interference.
(2) high-power electric motor electric spark generated by harmonic interference.
(3) fluorescent lamps, electronic ballasts produce interference.
(4) High-frequency switching power supply interference.
(5) generated by the telephone ringing current interference.
(6) Information processing device generates periodic pulse interference.
If the cabling system can not keep a safe distance from these sources may be used to reduce or eliminate shielding system interference sources above the interference of cabling system.
1.2 the source of interference from outside the data center building
Sources of interference from outside the data center architecture are:
Radar, radio transmission equipment, mobile phone base stations, high-voltage wire, electrified railways, lightning strike zones in the interference signal environment and so on.
Obviously intelligent building external interference sources have a high electric field strength, when external cabling systems exist one or more sources of interference should be shielded system.
1.3 sources of interference from the surrounding environment cabling system
Cabling system noise level ambient interference signal field strength or integrated wiring system also should be shielded to protect the system exceeds the following requirements.
(1) computer local area network, if the frequency of the interference signal is introduced l0kHz ~ 600MHz, its field strength of 1V / m; frequency of 600MHz ~ 2.8GHz interference signal field strength of 5V / m.
(2) telecommunications terminal equipment, is introduced through the signal line and other DC or AC frequency of the interfering signal introduced into 15 ~ 80MHz, the field strength of 3V / m (amplitude modulation 80%, 1kHz).
Terminal Equipment (3) with analog / digital terminal interface to provide telephone service, the noise level exceeds 40dB total bandwidth should be less than 200MHz.
(4) The background noise level should be at least 12dB smaller than the reference.
2, comprehensive sets of wiring system anti-jamming measures
Electric field strength interference waves emitted cabling system exceeds a predetermined value, whether factors that need protective measures is more complex, which is the most harmful anti-electromagnetic interference and electromagnetic radiation. EMI issues related to the cabling system can work properly; electromagnetic radiation is related to the safety of cabling system under normal operating conditions information from being stolen by other persons, or causing electromagnetic pollution.
Conducting integrated wiring systems engineering design must be in accordance with the requirements of the construction unit, carry out a detailed arrangement and design, selecting appropriate protective measures.
2.1 shielding measures to reduce electromagnetic interference
Metal casing (1) Information systems, cable shield and metal trunking and other buildings in the introduction frame or equipotential bonding. Information system lightning protection zone in which the magnetic field strength attenuation should be calculated, to take appropriate measures to shield according to the results.
(2) The data center should not be located in high-rise buildings, should lower center of the building. Related equipment to try to stay away from the building facade. Take appropriate measures in accordance with the requirements of lightning protection zones shield and information equipment, electromagnetic field generated when the lightning to the inner decay.
(3) The information device is a non-metallic housing and the shield of the building did not meet the requirements, the importance of information equipment room or equipment based on the direct installation of metal screen or shielded room, shielded metal shielded rooms and other potential connection with phase.
Outdoor line of shielding measures 2.2
Outdoor wiring shield to note the following.
(1) the need to protect the local potential should use shielded cables and both ends of the shielding layer is peer connections, the shield after the junction of the lightning protection zones should also be equipotential connection.
(2) the use of the cable metal-containing components, shall at all into the household of the metal plugs, metal tidal layer and the metal strengthening the core metal member equipotential connection.
Room (3) Building interconnecting cables should be laid in a metal pipe, metal pipe ends to be connected to other potential electrical connections and connections to bring each building. Cable conduits must be equipotential connection. If between adjacent buildings have power and communication cables, the grounding device should be connected to each other.
2.3 Strengthening internal cabling system structure and materials of immunity
This is mainly possible electromagnetic interference requirements for products and equipment may be affected by electromagnetic interference raised. Specific requirements in the manufacturing process is tested to the appropriate standard.
Overall, computer equipment, communications equipment and electronic equipment and other products shape the structure should be made of a metal material box, box, cabinet or shelf, making it in the form of a Faraday cage, a ground terminal, and well grounded. This ability to somehow enhance immunity and radiation protection equipment.
For cable selection Cabling system must meet the system requirements, combined with the buildings surrounding electromagnetic environment into account, usually anti-jamming capability and transmission capacity is the major consideration, but also to consider the economic cost.
Select cables and cabling system connecting hardware, when determining whether a category that you want to ensure consistency. If you choose to shield the cables and connecting hardware must be shielded, and have a good grounding system. Link cabling system commonly used twisted pair, UTP has the ability to absorb and emit electromagnetic waves.
2.4 Note from the equipment and transmission lines between the different sources of interference
In addition to the use of shielded cabling system, well grounded in order to improve their own immunity, radiation protection, but also as far away from interference sources, in order to reduce its impact on the normal operation of the system, improve the reliability of systems and equipment to make Data center cabling system truly become a standard, standard cabling system.
Through a number of experiments shows that when the interference source distance transmission line at different distances, the distortion degree of the transmission signal is different. Therefore, in the construction and installation process should pay attention to the relationship between the wiring system and the distance from the source of disturbance, in strict accordance with standard design, construction, and make the appropriate testing to ensure normal and reliable cabling system.
Friday, June 19, 2015
Why periphery and core are to be considered when selecting a CPU
New products bring to market quickly - with increasing design complexity. To help customers succeed, has been certified for ARM Accredited Engineer Future Electronics' MCU 300 engineers.
The time factor more than ever now plays a crucial role in product development and in meeting the timeframe for the launch. Choosing a core that does not exactly meet the requirements can jeopardize the entire schedule. The technical distributor Future Electronics is therefore on the intensive training of its field application.
300 engineers have been in the last year certified for ARM Accredited Engineer MCU and can now offer extensive assistance in the core selection. Uwe Knipping, technical solutions manager at Future Electronics, explains in an interview with the ELEKTRONIKPRAXIS which criteria are of particular importance.
ELEKTRONIKPRAXIS: What were the reasons for the ARM certification of engineers at Future Electronics?
Uwe Knipping: Through our work with customers, we found that great need for education is around choosing a suitable cores. As a technical distributor we set at the beginning of the development work on with our assistance around the choice of a core and place here the course for the project's success.
Participation in the ARM AAME program and the associated certification of Future Field Application Engineers will create the necessary basis of trust with our customers and at the same time laid the foundation to meet the different advisory requirements. By profound knowledge about ARM cores, we are even better able to design teams the customer from the start of a new project at the right decision to accompany architecture.
Why is this help today in the project so important?
Through ARM-based cores a vast variety of CPU choices has emerged in the last five years. Many manufacturers use the same core for its microcontroller, so that differentiation at first glance is not easy. Our experiences have shown that when choosing a microcontroller knowledge is tacitly over the core.
The manufacturer informed about what they have implemented around the core to the periphery. They provide customers with a wealth of material on data sheets and examples. Often but not find the time for individual advice on specific project. Here we jump and connect our core specific knowledge with the peripheral requirements.
Important is the vendor-neutral advice that we can with our overview of various ARM-based products and proprietary cores, such as the MIPS or AVR platforms, offer through our broad-based linecard in order to arrive at an optimal solution for specific customer needs.
The time factor more than ever now plays a crucial role in product development and in meeting the timeframe for the launch. Choosing a core that does not exactly meet the requirements can jeopardize the entire schedule. The technical distributor Future Electronics is therefore on the intensive training of its field application.
300 engineers have been in the last year certified for ARM Accredited Engineer MCU and can now offer extensive assistance in the core selection. Uwe Knipping, technical solutions manager at Future Electronics, explains in an interview with the ELEKTRONIKPRAXIS which criteria are of particular importance.
ELEKTRONIKPRAXIS: What were the reasons for the ARM certification of engineers at Future Electronics?
Uwe Knipping: Through our work with customers, we found that great need for education is around choosing a suitable cores. As a technical distributor we set at the beginning of the development work on with our assistance around the choice of a core and place here the course for the project's success.
Participation in the ARM AAME program and the associated certification of Future Field Application Engineers will create the necessary basis of trust with our customers and at the same time laid the foundation to meet the different advisory requirements. By profound knowledge about ARM cores, we are even better able to design teams the customer from the start of a new project at the right decision to accompany architecture.
Why is this help today in the project so important?
Through ARM-based cores a vast variety of CPU choices has emerged in the last five years. Many manufacturers use the same core for its microcontroller, so that differentiation at first glance is not easy. Our experiences have shown that when choosing a microcontroller knowledge is tacitly over the core.
The manufacturer informed about what they have implemented around the core to the periphery. They provide customers with a wealth of material on data sheets and examples. Often but not find the time for individual advice on specific project. Here we jump and connect our core specific knowledge with the peripheral requirements.
Important is the vendor-neutral advice that we can with our overview of various ARM-based products and proprietary cores, such as the MIPS or AVR platforms, offer through our broad-based linecard in order to arrive at an optimal solution for specific customer needs.
Wednesday, June 17, 2015
With a heart rate sensor Sony Smart Watch SmartBand 2 exposure
Usually in the form of stand or companies will disclose conference to showcase new products, or released well-made website to attract users to get as much attention. But do not take the unusual way Sony is using a new approach, although the second-generation SmartBand Smart Watch has not been released, but the relevant supporting applications have first landed Play store, but in the press before the page is offline application, but fast chips Foreign media have been preserved image.
Apparently Sony is developing a new generation of SmartBand, new product called "SmartBand2", increasing the heart rate sensor, capable of better qualified fitness tracking. The new application interface to Sony professional Lifelog application more professional, to get the best of both with a complete experience.
Contemporary with the same model, SmartBand2 sleep and can simultaneously track the number of steps varies depending on the mobile phone side dress remind transmission weather conditions, after the alarm can be set to vibrate. There are also dedicated buttons for all of the data can be retained screenshots to help you ah recorded statement is very meaningful moment.
Subscribe to:
Posts (Atom)